300 Series Inverted Bucket Steam Trap

Vertical installation (bottom inlet, top outlet) maximum pressure difference 45 bar, maximum displacement up to 9072 kg/h

 

Materials

Valve body, valve cover: A105/F11

Valve seat: Martensitic stainless steel

Valve disc: Martensitic stainless steel

Other internal parts: stainless steel

Get A Quote
Product Description
Selection Restrictions (Alloy) Restrictions (carbon steel) Installation Instructions
•Built-in stainless steel check valve (CV)
•Borne pass needle (BVSW)
• Design pressure (PMA): 100bar
• Maximum operating pressure (PMO): 45bar
• Maximum operating temperature (TMO): 450°C
• Design pressure (PMA): 100bar
• Maximum operating pressure (PMO): 45bar
• Maximum operating temperature (TMO): 343°C
Keep the valve body vertical during installation to ensure vertical up and down movement of the bucket.

 

Operation in overheating condition For superheated steam
Under normal working conditions, what generally enters the inverted bucket steam trap is saturated steam and condensate. Superheated steam may also enter, but its condensation rate is basically equal to that of the steam in the valve. Therefore, regardless of the superheat, the steam trap is always at saturated temperature (or slightly lower). Do not oversize the orifice; limiting the orifice size is desirable.
Specific grinding of the disc and seat, as well as extended inlet pipe and check valves.
Provide a set with sufficient diameter and length.
Provide sufficient length of inlet pipe so that the trap is lower than the main line.
Do not insulate the trap or inlet pipe.

 

 

Dimensions/Weight (approximate) mm and Kg

Model
310(FW) 312(FW) 313(FW) 314(FW) 315(FW) 316(FW)
310(FF) 312(FF) 313(FF) 314(FF) 315(FF) 316(FF)
Nominal diameter  15 20 15 20 25 15 20 25 25 32 40 50 25 32 40 50 32 40 50
A(mm) 202 259 292 348 364 435
A1(mm) 306 313 352 367 414 500
A2(mm) 315 320 360 380 395 405 410 430 480 500 515 535 550 605 610
B(mm) 117 171 203 219 248 302
K(mm) 15 32 37 37 45 54
Weight(Kg) Thread 4 12 21 29 42 70
Flange 5 14 23 31 44 75

 

Technical Parameters

Model 310 312 313 314 315 316
Connection Type Threaded, socket welded, fabricated flanges
Installation vertical
Maximum working pressure difference (PMX)  (A) 1bar 1bar 1bar 1bar 1bar 1bar
(B) 2bar 2bar 2bar 2bar 2bar 2.8bar
(C) 4.8bar 5 bar 4bar 5.5 bar 4bar 4.1bar
(D) 8.6 bar 8.6 bar 5.5 bar 8.6 bar 6.9 bar 5.5 bar
(AND) 14bar 14bar 8.6 bar 12.4bar 12.4bar 8.6 bar
(F) 17bar 24bar 12.4bar 17bar 19bar 12.4bar
(G) 28bar 41bar 19bar 26 bar 24bar 17bar
(H) / / 31 bar 38bar 34bar 25.5 bar
(I) / / 45bar 45bar 45bar 34bar
(J) / / / / / 41bar
(K) / / / / / 45bar
(L) / / / / / /

 